Professor Richard Schilling: Cardiology
Search

Professor Richard Schilling

Cardiology

 

  • Fee assured
Overview

Specialises in

About me

Professor Richard Schilling qualified from St Thomas’ Hospital in 1989 and was appointed as a consultant cardiologist at St Bartholomew’s and the Royal London NHS trust in January 2001.
His current practice involves all aspects of electrophysiology and management of cardiac arrhythmia including catheter ablation, implantation of pacemakers and cardiac defibrillators and also cardiac resynchronisation therapy for heart failure patients.
He has a special interest in atrial fibrillation and performs over 200 AF ablations a year using the latest 3D mapping techniques. He is also trained in transoesophageal echocardiogram.

Areas of interest

Atrial Fibrillation Ablation; Ablation; Catheter Ablation; Palpitation; Syncope; Blackouts; AF; SVT; VT; Arrhythmias; Cardiac rhythm management; Cardiac electrophysiology

Medical secretaries

Anaesthetists worked with (Bupa members, please ask your consultant whether your anaesthetist is fee-assured)

About me
My outcomes
My qualifications & training
My private practice
Consultant's practices
Information for healthcare professionals

Information for healthcare professionals (Bupa patients only, last 12 months)

Procedures completed

  • 20110

    ECG (including reporting) - (>50)

  • K5760

    Ablation of atrial fibrillation by isolation of the pulmonary veins (including mapping) - (5-50)

    London Bridge Hospital (5-50)

  • X5020

    External cardioversion - (5-50)

    London Bridge Hospital (1-5)

  • K5710

    Ablation of atrio-ventricular junction (including mapping) - (1-5)

    London Bridge Hospital (1-5)

  • X3510

    IV sedation administered by operator - (1-5)

    London Bridge Hospital (1-5)

  • 20141

    Continuous ambulatory ECG for up to 72 hours (including reporting) - (1-5)

  • K5730

    Ablation of atrial arrhythmia (including mapping) - (1-5)

  • 20142

    Insertion of implantable ECG loop recorder (including reporting) - (1-5)

  • K6000

    Cardiac pacemaker system introduced through vein (single chamber) - (1-5)

  • 20140

    24 hour ECG Holter (including reporting) - (1-5)

  • Show All (16)...
Edit details Print page

The information contained on Finder is submitted by consultants, therapists and facilities, and is declared by these third parties to be correct and compliant with the standards and codes of conduct specified by their relevant regulatory body. Bupa cannot guarantee the accuracy of all of the information provided.

You can find out more about the data and information on Finder and our website terms of use here.